Dialogflow v3 API - Class Form.Types.Parameter.Types.FillBehavior (2.9.0)

public sealed class Form.Types.Parameter.Types.FillBehavior : IMessage<Form.Types.Parameter.Types.FillBehavior>, IEquatable<Form.Types.Parameter.Types.FillBehavior>, IDeepCloneable<Form.Types.Parameter.Types.FillBehavior>, IBufferMessage, IMessage

Reference documentation and code samples for the Dialogflow v3 API class Form.Types.Parameter.Types.FillBehavior.

Configuration for how the filling of a parameter should be handled.

Inheritance

object > Form.Types.Parameter.Types.FillBehavior

Namespace

Google.Cloud.Dialogflow.Cx.V3

Assembly

Google.Cloud.Dialogflow.Cx.V3.dll

Constructors

FillBehavior()

public FillBehavior()

FillBehavior(FillBehavior)

public FillBehavior(Form.Types.Parameter.Types.FillBehavior other)
Parameter
NameDescription
otherFormTypesParameterTypesFillBehavior

Properties

InitialPromptFulfillment

public Fulfillment InitialPromptFulfillment { get; set; }

Required. The fulfillment to provide the initial prompt that the agent can present to the user in order to fill the parameter.

Property Value
TypeDescription
Fulfillment

RepromptEventHandlers

public RepeatedField<EventHandler> RepromptEventHandlers { get; }

The handlers for parameter-level events, used to provide reprompt for the parameter or transition to a different page/flow. The supported events are:

  • sys.no-match-<N>, where N can be from 1 to 6
  • sys.no-match-default
  • sys.no-input-<N>, where N can be from 1 to 6
  • sys.no-input-default
  • sys.invalid-parameter

initial_prompt_fulfillment provides the first prompt for the parameter.

If the user's response does not fill the parameter, a no-match/no-input event will be triggered, and the fulfillment associated with the sys.no-match-1/sys.no-input-1 handler (if defined) will be called to provide a prompt. The sys.no-match-2/sys.no-input-2 handler (if defined) will respond to the next no-match/no-input event, and so on.

A sys.no-match-default or sys.no-input-default handler will be used to handle all following no-match/no-input events after all numbered no-match/no-input handlers for the parameter are consumed.

A sys.invalid-parameter handler can be defined to handle the case where the parameter values have been invalidated by webhook. For example, if the user's response fill the parameter, however the parameter was invalidated by webhook, the fulfillment associated with the sys.invalid-parameter handler (if defined) will be called to provide a prompt.

If the event handler for the corresponding event can't be found on the parameter, initial_prompt_fulfillment will be re-prompted.

Property Value
TypeDescription
RepeatedFieldEventHandler