Class InterconnectDiagnosticsLinkOpticalPower (0.2.1)

InterconnectDiagnosticsLinkOpticalPower(
    mapping=None, *, ignore_unknown_fields=False, **kwargs
)

Attributes

NameDescription
state google.cloud.compute_v1.types.InterconnectDiagnosticsLinkOpticalPower.State
The status of the current value when compared to the warning and alarm levels for the receiving or transmitting transceiver. Possible states include: - OK: The value has not crossed a warning threshold. - LOW_WARNING: The value has crossed below the low warning threshold. - HIGH_WARNING: The value has crossed above the high warning threshold. - LOW_ALARM: The value has crossed below the low alarm threshold. - HIGH_ALARM: The value has crossed above the high alarm threshold.
value float
Value of the current receiving or transmitting optical power, read in dBm. Take a known good optical value, give it a 10% margin and trigger warnings relative to that value. In general, a -7dBm warning and a -11dBm alarm are good optical value estimates for most links.

Classes

State

State(value)

The status of the current value when compared to the warning and alarm levels for the receiving or transmitting transceiver. Possible states include:

  • OK: The value has not crossed a warning threshold.
  • LOW_WARNING: The value has crossed below the low warning threshold.
  • HIGH_WARNING: The value has crossed above the high warning threshold.
  • LOW_ALARM: The value has crossed below the low alarm threshold.
  • HIGH_ALARM: The value has crossed above the high alarm threshold.