Interface InterconnectDiagnosticsLinkOpticalPowerOrBuilder (1.31.0)

public interface InterconnectDiagnosticsLinkOpticalPowerOrBuilder extends MessageOrBuilder

Implements

MessageOrBuilder

Methods

getState()

public abstract String getState()

The status of the current value when compared to the warning and alarm levels for the receiving or transmitting transceiver. Possible states include: - OK: The value has not crossed a warning threshold. - LOW_WARNING: The value has crossed below the low warning threshold. - HIGH_WARNING: The value has crossed above the high warning threshold. - LOW_ALARM: The value has crossed below the low alarm threshold. - HIGH_ALARM: The value has crossed above the high alarm threshold. Check the State enum for the list of possible values.

optional string state = 109757585;

Returns
TypeDescription
String

The state.

getStateBytes()

public abstract ByteString getStateBytes()

The status of the current value when compared to the warning and alarm levels for the receiving or transmitting transceiver. Possible states include: - OK: The value has not crossed a warning threshold. - LOW_WARNING: The value has crossed below the low warning threshold. - HIGH_WARNING: The value has crossed above the high warning threshold. - LOW_ALARM: The value has crossed below the low alarm threshold. - HIGH_ALARM: The value has crossed above the high alarm threshold. Check the State enum for the list of possible values.

optional string state = 109757585;

Returns
TypeDescription
ByteString

The bytes for state.

getValue()

public abstract float getValue()

Value of the current receiving or transmitting optical power, read in dBm. Take a known good optical value, give it a 10% margin and trigger warnings relative to that value. In general, a -7dBm warning and a -11dBm alarm are good optical value estimates for most links.

optional float value = 111972721;

Returns
TypeDescription
float

The value.

hasState()

public abstract boolean hasState()

The status of the current value when compared to the warning and alarm levels for the receiving or transmitting transceiver. Possible states include: - OK: The value has not crossed a warning threshold. - LOW_WARNING: The value has crossed below the low warning threshold. - HIGH_WARNING: The value has crossed above the high warning threshold. - LOW_ALARM: The value has crossed below the low alarm threshold. - HIGH_ALARM: The value has crossed above the high alarm threshold. Check the State enum for the list of possible values.

optional string state = 109757585;

Returns
TypeDescription
boolean

Whether the state field is set.

hasValue()

public abstract boolean hasValue()

Value of the current receiving or transmitting optical power, read in dBm. Take a known good optical value, give it a 10% margin and trigger warnings relative to that value. In general, a -7dBm warning and a -11dBm alarm are good optical value estimates for most links.

optional float value = 111972721;

Returns
TypeDescription
boolean

Whether the value field is set.