- 1.63.0 (latest)
- 1.62.0
- 1.61.0
- 1.59.0
- 1.58.0
- 1.57.0
- 1.56.0
- 1.55.0
- 1.54.0
- 1.53.0
- 1.52.0
- 1.51.0
- 1.50.0
- 1.49.0
- 1.47.0
- 1.46.0
- 1.45.0
- 1.44.0
- 1.43.0
- 1.42.0
- 1.41.0
- 1.40.0
- 1.39.0
- 1.38.0
- 1.37.0
- 1.34.0
- 1.33.0
- 1.32.0
- 1.31.0
- 1.30.0
- 1.29.0
- 1.28.0
- 1.27.0
- 1.26.0
- 1.25.0
- 1.24.0
- 1.23.0
- 1.22.0
- 1.21.0
- 1.20.0
- 1.19.0
- 1.18.0
- 1.17.0
- 1.16.0
- 1.15.0
- 1.14.0
- 1.13.0
- 1.12.1
- 1.11.0
- 1.9.1
- 1.8.1
- 1.7.2
- 1.6.0-beta
public interface RouterBgpPeerBfdOrBuilder extends MessageOrBuilder
Implements
MessageOrBuilderMethods
getMinReceiveInterval()
public abstract int getMinReceiveInterval()
The minimum interval, in milliseconds, between BFD control packets received from the peer router. The actual value is negotiated between the two routers and is equal to the greater of this value and the transmit interval of the other router. If set, this value must be between 1000 and 30000. The default is 1000.
optional uint32 min_receive_interval = 186981614;
Returns | |
---|---|
Type | Description |
int | The minReceiveInterval. |
getMinTransmitInterval()
public abstract int getMinTransmitInterval()
The minimum interval, in milliseconds, between BFD control packets transmitted to the peer router. The actual value is negotiated between the two routers and is equal to the greater of this value and the corresponding receive interval of the other router. If set, this value must be between 1000 and 30000. The default is 1000.
optional uint32 min_transmit_interval = 523282631;
Returns | |
---|---|
Type | Description |
int | The minTransmitInterval. |
getMultiplier()
public abstract int getMultiplier()
The number of consecutive BFD packets that must be missed before BFD declares that a peer is unavailable. If set, the value must be a value between 5 and 16. The default is 5.
optional uint32 multiplier = 191331777;
Returns | |
---|---|
Type | Description |
int | The multiplier. |
getSessionInitializationMode()
public abstract String getSessionInitializationMode()
The BFD session initialization mode for this BGP peer. If set to ACTIVE, the Cloud Router will initiate the BFD session for this BGP peer. If set to PASSIVE, the Cloud Router will wait for the peer router to initiate the BFD session for this BGP peer. If set to DISABLED, BFD is disabled for this BGP peer. The default is DISABLED. Check the SessionInitializationMode enum for the list of possible values.
optional string session_initialization_mode = 105957049;
Returns | |
---|---|
Type | Description |
String | The sessionInitializationMode. |
getSessionInitializationModeBytes()
public abstract ByteString getSessionInitializationModeBytes()
The BFD session initialization mode for this BGP peer. If set to ACTIVE, the Cloud Router will initiate the BFD session for this BGP peer. If set to PASSIVE, the Cloud Router will wait for the peer router to initiate the BFD session for this BGP peer. If set to DISABLED, BFD is disabled for this BGP peer. The default is DISABLED. Check the SessionInitializationMode enum for the list of possible values.
optional string session_initialization_mode = 105957049;
Returns | |
---|---|
Type | Description |
ByteString | The bytes for sessionInitializationMode. |
hasMinReceiveInterval()
public abstract boolean hasMinReceiveInterval()
The minimum interval, in milliseconds, between BFD control packets received from the peer router. The actual value is negotiated between the two routers and is equal to the greater of this value and the transmit interval of the other router. If set, this value must be between 1000 and 30000. The default is 1000.
optional uint32 min_receive_interval = 186981614;
Returns | |
---|---|
Type | Description |
boolean | Whether the minReceiveInterval field is set. |
hasMinTransmitInterval()
public abstract boolean hasMinTransmitInterval()
The minimum interval, in milliseconds, between BFD control packets transmitted to the peer router. The actual value is negotiated between the two routers and is equal to the greater of this value and the corresponding receive interval of the other router. If set, this value must be between 1000 and 30000. The default is 1000.
optional uint32 min_transmit_interval = 523282631;
Returns | |
---|---|
Type | Description |
boolean | Whether the minTransmitInterval field is set. |
hasMultiplier()
public abstract boolean hasMultiplier()
The number of consecutive BFD packets that must be missed before BFD declares that a peer is unavailable. If set, the value must be a value between 5 and 16. The default is 5.
optional uint32 multiplier = 191331777;
Returns | |
---|---|
Type | Description |
boolean | Whether the multiplier field is set. |
hasSessionInitializationMode()
public abstract boolean hasSessionInitializationMode()
The BFD session initialization mode for this BGP peer. If set to ACTIVE, the Cloud Router will initiate the BFD session for this BGP peer. If set to PASSIVE, the Cloud Router will wait for the peer router to initiate the BFD session for this BGP peer. If set to DISABLED, BFD is disabled for this BGP peer. The default is DISABLED. Check the SessionInitializationMode enum for the list of possible values.
optional string session_initialization_mode = 105957049;
Returns | |
---|---|
Type | Description |
boolean | Whether the sessionInitializationMode field is set. |