public static final class NodeGroupAutoscalingPolicy.Builder extends GeneratedMessageV3.Builder<NodeGroupAutoscalingPolicy.Builder> implements NodeGroupAutoscalingPolicyOrBuilder
Protobuf type google.cloud.compute.v1.NodeGroupAutoscalingPolicy
Inherited Members
com.google.protobuf.GeneratedMessageV3.Builder.getUnknownFieldSetBuilder()
com.google.protobuf.GeneratedMessageV3.Builder.mergeUnknownLengthDelimitedField(int,com.google.protobuf.ByteString)
com.google.protobuf.GeneratedMessageV3.Builder.mergeUnknownVarintField(int,int)
com.google.protobuf.GeneratedMessageV3.Builder.parseUnknownField(com.google.protobuf.CodedInputStream,com.google.protobuf.ExtensionRegistryLite,int)
com.google.protobuf.GeneratedMessageV3.Builder.setUnknownFieldSetBuilder(com.google.protobuf.UnknownFieldSet.Builder)
Static Methods
getDescriptor()
public static final Descriptors.Descriptor getDescriptor()
Methods
addRepeatedField(Descriptors.FieldDescriptor field, Object value)
public NodeGroupAutoscalingPolicy.Builder addRepeatedField(Descriptors.FieldDescriptor field, Object value)
Overrides
build()
public NodeGroupAutoscalingPolicy build()
buildPartial()
public NodeGroupAutoscalingPolicy buildPartial()
clear()
public NodeGroupAutoscalingPolicy.Builder clear()
Overrides
clearField(Descriptors.FieldDescriptor field)
public NodeGroupAutoscalingPolicy.Builder clearField(Descriptors.FieldDescriptor field)
Overrides
clearMaxNodes()
public NodeGroupAutoscalingPolicy.Builder clearMaxNodes()
The maximum number of nodes that the group should have. Must be set if autoscaling is enabled. Maximum value allowed is 100.
optional int32 max_nodes = 297762838;
clearMinNodes()
public NodeGroupAutoscalingPolicy.Builder clearMinNodes()
The minimum number of nodes that the group should have.
optional int32 min_nodes = 533370500;
clearMode()
public NodeGroupAutoscalingPolicy.Builder clearMode()
The autoscaling mode. Set to one of: ON, OFF, or ONLY_SCALE_OUT. For more information, see Autoscaler modes.
Check the Mode enum for the list of possible values.
optional string mode = 3357091;
clearOneof(Descriptors.OneofDescriptor oneof)
public NodeGroupAutoscalingPolicy.Builder clearOneof(Descriptors.OneofDescriptor oneof)
Overrides
clone()
public NodeGroupAutoscalingPolicy.Builder clone()
Overrides
getDefaultInstanceForType()
public NodeGroupAutoscalingPolicy getDefaultInstanceForType()
getDescriptorForType()
public Descriptors.Descriptor getDescriptorForType()
Overrides
getMaxNodes()
The maximum number of nodes that the group should have. Must be set if autoscaling is enabled. Maximum value allowed is 100.
optional int32 max_nodes = 297762838;
Returns |
---|
Type | Description |
int | The maxNodes.
|
getMinNodes()
The minimum number of nodes that the group should have.
optional int32 min_nodes = 533370500;
Returns |
---|
Type | Description |
int | The minNodes.
|
getMode()
The autoscaling mode. Set to one of: ON, OFF, or ONLY_SCALE_OUT. For more information, see Autoscaler modes.
Check the Mode enum for the list of possible values.
optional string mode = 3357091;
Returns |
---|
Type | Description |
String | The mode.
|
getModeBytes()
public ByteString getModeBytes()
The autoscaling mode. Set to one of: ON, OFF, or ONLY_SCALE_OUT. For more information, see Autoscaler modes.
Check the Mode enum for the list of possible values.
optional string mode = 3357091;
Returns |
---|
Type | Description |
ByteString | The bytes for mode.
|
hasMaxNodes()
public boolean hasMaxNodes()
The maximum number of nodes that the group should have. Must be set if autoscaling is enabled. Maximum value allowed is 100.
optional int32 max_nodes = 297762838;
Returns |
---|
Type | Description |
boolean | Whether the maxNodes field is set.
|
hasMinNodes()
public boolean hasMinNodes()
The minimum number of nodes that the group should have.
optional int32 min_nodes = 533370500;
Returns |
---|
Type | Description |
boolean | Whether the minNodes field is set.
|
hasMode()
The autoscaling mode. Set to one of: ON, OFF, or ONLY_SCALE_OUT. For more information, see Autoscaler modes.
Check the Mode enum for the list of possible values.
optional string mode = 3357091;
Returns |
---|
Type | Description |
boolean | Whether the mode field is set.
|
internalGetFieldAccessorTable()
protected GeneratedMessageV3.FieldAccessorTable internalGetFieldAccessorTable()
Overrides
isInitialized()
public final boolean isInitialized()
Overrides
mergeFrom(NodeGroupAutoscalingPolicy other)
public NodeGroupAutoscalingPolicy.Builder mergeFrom(NodeGroupAutoscalingPolicy other)
public NodeGroupAutoscalingPolicy.Builder mergeFrom(CodedInputStream input, ExtensionRegistryLite extensionRegistry)
Overrides
mergeFrom(Message other)
public NodeGroupAutoscalingPolicy.Builder mergeFrom(Message other)
Parameter |
---|
Name | Description |
other | Message
|
Overrides
mergeUnknownFields(UnknownFieldSet unknownFields)
public final NodeGroupAutoscalingPolicy.Builder mergeUnknownFields(UnknownFieldSet unknownFields)
Overrides
setField(Descriptors.FieldDescriptor field, Object value)
public NodeGroupAutoscalingPolicy.Builder setField(Descriptors.FieldDescriptor field, Object value)
Overrides
setMaxNodes(int value)
public NodeGroupAutoscalingPolicy.Builder setMaxNodes(int value)
The maximum number of nodes that the group should have. Must be set if autoscaling is enabled. Maximum value allowed is 100.
optional int32 max_nodes = 297762838;
Parameter |
---|
Name | Description |
value | int
The maxNodes to set.
|
setMinNodes(int value)
public NodeGroupAutoscalingPolicy.Builder setMinNodes(int value)
The minimum number of nodes that the group should have.
optional int32 min_nodes = 533370500;
Parameter |
---|
Name | Description |
value | int
The minNodes to set.
|
setMode(String value)
public NodeGroupAutoscalingPolicy.Builder setMode(String value)
The autoscaling mode. Set to one of: ON, OFF, or ONLY_SCALE_OUT. For more information, see Autoscaler modes.
Check the Mode enum for the list of possible values.
optional string mode = 3357091;
Parameter |
---|
Name | Description |
value | String
The mode to set.
|
setModeBytes(ByteString value)
public NodeGroupAutoscalingPolicy.Builder setModeBytes(ByteString value)
The autoscaling mode. Set to one of: ON, OFF, or ONLY_SCALE_OUT. For more information, see Autoscaler modes.
Check the Mode enum for the list of possible values.
optional string mode = 3357091;
Parameter |
---|
Name | Description |
value | ByteString
The bytes for mode to set.
|
setRepeatedField(Descriptors.FieldDescriptor field, int index, Object value)
public NodeGroupAutoscalingPolicy.Builder setRepeatedField(Descriptors.FieldDescriptor field, int index, Object value)
Overrides
setUnknownFields(UnknownFieldSet unknownFields)
public final NodeGroupAutoscalingPolicy.Builder setUnknownFields(UnknownFieldSet unknownFields)
Overrides