Class SubnetworkLogConfig (0.9.0)

SubnetworkLogConfig(mapping=None, *, ignore_unknown_fields=False, **kwargs)

The available logging options for this subnetwork.

Attributes

NameDescription
aggregation_interval str
Can only be specified if VPC flow logging for this subnetwork is enabled. Toggles the aggregation interval for collecting flow logs. Increasing the interval time will reduce the amount of generated flow logs for long lasting connections. Default is an interval of 5 seconds per connection. Check the AggregationInterval enum for the list of possible values. This field is a member of oneof_ _aggregation_interval.
enable bool
Whether to enable flow logging for this subnetwork. If this field is not explicitly set, it will not appear in get listings. If not set the default behavior is to disable flow logging. This field is a member of oneof_ _enable.
filter_expr str
Can only be specified if VPC flow logs for this subnetwork is enabled. Export filter used to define which VPC flow logs should be logged. This field is a member of oneof_ _filter_expr.
flow_sampling float
Can only be specified if VPC flow logging for this subnetwork is enabled. The value of the field must be in [0, 1]. Set the sampling rate of VPC flow logs within the subnetwork where 1.0 means all collected logs are reported and 0.0 means no logs are reported. Default is 0.5, which means half of all collected logs are reported. This field is a member of oneof_ _flow_sampling.
metadata str
Can only be specified if VPC flow logs for this subnetwork is enabled. Configures whether all, none or a subset of metadata fields should be added to the reported VPC flow logs. Default is EXCLUDE_ALL_METADATA. Check the Metadata enum for the list of possible values. This field is a member of oneof_ _metadata.
metadata_fields Sequence[str]
Can only be specified if VPC flow logs for this subnetwork is enabled and "metadata" was set to CUSTOM_METADATA.

Classes

AggregationInterval

AggregationInterval(value)

Can only be specified if VPC flow logging for this subnetwork is enabled. Toggles the aggregation interval for collecting flow logs. Increasing the interval time will reduce the amount of generated flow logs for long lasting connections. Default is an interval of 5 seconds per connection.

Metadata

Metadata(value)

Can only be specified if VPC flow logs for this subnetwork is enabled. Configures whether all, none or a subset of metadata fields should be added to the reported VPC flow logs. Default is EXCLUDE_ALL_METADATA.