Compute V1 Client - Class SubnetworkLogConfig (1.5.0)

Reference documentation and code samples for the Compute V1 Client class SubnetworkLogConfig.

The available logging options for this subnetwork.

Generated from protobuf message google.cloud.compute.v1.SubnetworkLogConfig

Methods

__construct

Constructor.

Parameters
NameDescription
data array

Optional. Data for populating the Message object.

↳ aggregation_interval string

Can only be specified if VPC flow logging for this subnetwork is enabled. Toggles the aggregation interval for collecting flow logs. Increasing the interval time will reduce the amount of generated flow logs for long lasting connections. Default is an interval of 5 seconds per connection. Check the AggregationInterval enum for the list of possible values.

↳ enable bool

Whether to enable flow logging for this subnetwork. If this field is not explicitly set, it will not appear in get listings. If not set the default behavior is determined by the org policy, if there is no org policy specified, then it will default to disabled.

↳ filter_expr string

Can only be specified if VPC flow logs for this subnetwork is enabled. The filter expression is used to define which VPC flow logs should be exported to Cloud Logging.

↳ flow_sampling float

Can only be specified if VPC flow logging for this subnetwork is enabled. The value of the field must be in [0, 1]. Set the sampling rate of VPC flow logs within the subnetwork where 1.0 means all collected logs are reported and 0.0 means no logs are reported. Default is 0.5 unless otherwise specified by the org policy, which means half of all collected logs are reported.

↳ metadata string

Can only be specified if VPC flow logs for this subnetwork is enabled. Configures whether all, none or a subset of metadata fields should be added to the reported VPC flow logs. Default is EXCLUDE_ALL_METADATA. Check the Metadata enum for the list of possible values.

↳ metadata_fields array

Can only be specified if VPC flow logs for this subnetwork is enabled and "metadata" was set to CUSTOM_METADATA.

getAggregationInterval

Can only be specified if VPC flow logging for this subnetwork is enabled. Toggles the aggregation interval for collecting flow logs. Increasing the interval time will reduce the amount of generated flow logs for long lasting connections. Default is an interval of 5 seconds per connection.

Check the AggregationInterval enum for the list of possible values.

Generated from protobuf field optional string aggregation_interval = 174919042;

Returns
TypeDescription
string

hasAggregationInterval

clearAggregationInterval

setAggregationInterval

Can only be specified if VPC flow logging for this subnetwork is enabled. Toggles the aggregation interval for collecting flow logs. Increasing the interval time will reduce the amount of generated flow logs for long lasting connections. Default is an interval of 5 seconds per connection.

Check the AggregationInterval enum for the list of possible values.

Generated from protobuf field optional string aggregation_interval = 174919042;

Parameter
NameDescription
var string
Returns
TypeDescription
$this

getEnable

Whether to enable flow logging for this subnetwork. If this field is not explicitly set, it will not appear in get listings. If not set the default behavior is determined by the org policy, if there is no org policy specified, then it will default to disabled.

Generated from protobuf field optional bool enable = 311764355;

Returns
TypeDescription
bool

hasEnable

clearEnable

setEnable

Whether to enable flow logging for this subnetwork. If this field is not explicitly set, it will not appear in get listings. If not set the default behavior is determined by the org policy, if there is no org policy specified, then it will default to disabled.

Generated from protobuf field optional bool enable = 311764355;

Parameter
NameDescription
var bool
Returns
TypeDescription
$this

getFilterExpr

Can only be specified if VPC flow logs for this subnetwork is enabled. The filter expression is used to define which VPC flow logs should be exported to Cloud Logging.

Generated from protobuf field optional string filter_expr = 183374428;

Returns
TypeDescription
string

hasFilterExpr

clearFilterExpr

setFilterExpr

Can only be specified if VPC flow logs for this subnetwork is enabled. The filter expression is used to define which VPC flow logs should be exported to Cloud Logging.

Generated from protobuf field optional string filter_expr = 183374428;

Parameter
NameDescription
var string
Returns
TypeDescription
$this

getFlowSampling

Can only be specified if VPC flow logging for this subnetwork is enabled. The value of the field must be in [0, 1]. Set the sampling rate of VPC flow logs within the subnetwork where 1.0 means all collected logs are reported and 0.0 means no logs are reported. Default is 0.5 unless otherwise specified by the org policy, which means half of all collected logs are reported.

Generated from protobuf field optional float flow_sampling = 530150360;

Returns
TypeDescription
float

hasFlowSampling

clearFlowSampling

setFlowSampling

Can only be specified if VPC flow logging for this subnetwork is enabled. The value of the field must be in [0, 1]. Set the sampling rate of VPC flow logs within the subnetwork where 1.0 means all collected logs are reported and 0.0 means no logs are reported. Default is 0.5 unless otherwise specified by the org policy, which means half of all collected logs are reported.

Generated from protobuf field optional float flow_sampling = 530150360;

Parameter
NameDescription
var float
Returns
TypeDescription
$this

getMetadata

Can only be specified if VPC flow logs for this subnetwork is enabled. Configures whether all, none or a subset of metadata fields should be added to the reported VPC flow logs. Default is EXCLUDE_ALL_METADATA.

Check the Metadata enum for the list of possible values.

Generated from protobuf field optional string metadata = 86866735;

Returns
TypeDescription
string

hasMetadata

clearMetadata

setMetadata

Can only be specified if VPC flow logs for this subnetwork is enabled. Configures whether all, none or a subset of metadata fields should be added to the reported VPC flow logs. Default is EXCLUDE_ALL_METADATA.

Check the Metadata enum for the list of possible values.

Generated from protobuf field optional string metadata = 86866735;

Parameter
NameDescription
var string
Returns
TypeDescription
$this

getMetadataFields

Can only be specified if VPC flow logs for this subnetwork is enabled and "metadata" was set to CUSTOM_METADATA.

Generated from protobuf field repeated string metadata_fields = 378461641;

Returns
TypeDescription
Google\Protobuf\Internal\RepeatedField

setMetadataFields

Can only be specified if VPC flow logs for this subnetwork is enabled and "metadata" was set to CUSTOM_METADATA.

Generated from protobuf field repeated string metadata_fields = 378461641;

Parameter
NameDescription
var string[]
Returns
TypeDescription
$this